Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Dent ; 39(2): 163-70, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21126556

RESUMO

OBJECTIVES: This in vitro study aimed to investigate the protective effect of four commercial novel agents against erosion. METHODS: Ninety human molars were distributed into 9 groups, and after incubation in human saliva for 2 h, a pellicle was formed. Subsequently, the specimens were submitted to demineralization (orange juice, pH 3.6, 3 min) and remineralization (paste slurry containing one of the tested novel agents, 3 min) cycles, two times per day, for 4 days. The tested agents were: (1) DenShield Tooth; active ingredient: 7.5% W/W NovaMin(®) (calcium sodium phosphosilicate); (2) Nanosensitive hca; active ingredient: 7.5% W/W NovaMin(®); (3) GC Tooth Mousse; active ingredient: 10% Recaldent™ (CPP-ACP); (4) GC MI Paste Plus; active ingredients: 10% Recaldent™, 900 ppm fluoride. Two experimental procedures were performed: in procedure 1, the tested agents were applied prior to the erosive attack, and in procedure 2 after the erosive attack. A control group receiving no prophylactic treatment was included. Surface nanohardness (SNH) of enamel specimens was measured after pellicle formation and after completion of daily cyclic treatment. RESULTS: SNH significantly decreased at the end of the experiment for all groups (p<0.05). In both procedures, there was no statistically significant difference between the control group and those treated with paste slurries (p>0.05). In addition, the changes in SNH (ΔSNH=SNHbaseline-SNHfinal) did not show statistically significant difference between both procedures (p>0.05). CONCLUSION: Tooth erosion cannot be prevented or repaired by these novel agents, regardless of fluoride content.


Assuntos
Preparações Farmacêuticas Odontológicas/uso terapêutico , Erosão Dentária/prevenção & controle , Remineralização Dentária/métodos , Bebidas/efeitos adversos , Caseínas/administração & dosagem , Caseínas/uso terapêutico , Citrus , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/ultraestrutura , Película Dentária/efeitos dos fármacos , Película Dentária/ultraestrutura , Fluoretos/administração & dosagem , Fluoretos/uso terapêutico , Frutas , Vidro , Dureza , Humanos , Concentração de Íons de Hidrogênio , Teste de Materiais , Microscopia Eletrônica de Varredura , Preparações Farmacêuticas Odontológicas/administração & dosagem , Saliva Artificial , Temperatura , Fatores de Tempo , Erosão Dentária/patologia
2.
Caries Res ; 42(1): 62-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18087151

RESUMO

The aim of the present study was to test the impact of different toothpastes on the prevention of erosion. Enamel demineralization and remineralization were monitored using surface microhardness (SMH) measurements. Human enamel specimens were treated following two different procedures: (1) incubation in toothpaste slurry followed by acid softening and artificial saliva exposure; (2) acid softening followed by incubation in toothpaste slurry and artificial saliva exposure. For the control procedure, toothpaste treatment was excluded. The following toothpastes were tested: Zendium, Sensodyne Proschmelz (Pronamel), Prodent Rocket Power, Meridol and Signal active. Normalized SMH values compared to the baseline (= 1.00) after 1-hour artificial saliva exposure for procedure 1 (respectively for procedure 2) were as follows (mean: 95% CI): Sensodyne Proschmelz 0.97: 0.93, 1.00 (0.92: 0.90, 0.94), Zendium 0.97: 0.94, 1.00 (0.89: 0.83, 0.95), Meridol 0.97: 0.94, 1.00 (0.94: 0.92, 0.96), Signal active 0.94: 0.91, 0.97 (0.95: 0.91, 0.99), Prodent Rocket Power 0.92: 0.90, 0.94 (0.93: 0.89, 0.97) and control 0.91: 0.88, 0.94. Further exposure to artificial saliva for up to 4 h showed no significant improvement of SMH. Regression analyses revealed a significant impact of the applied procedure. Incubation in toothpaste slurries before the acid challenge seems to be favorable to prevent erosion. None of the tested toothpastes showed statistically significant better protection than another against an erosive attack.


Assuntos
Erosão Dentária/prevenção & controle , Cremes Dentais/uso terapêutico , Dente Pré-Molar , Esmalte Dentário/patologia , Solubilidade do Esmalte Dentário , Dureza , Humanos , Análise de Regressão , Saliva Artificial/química , Saliva Artificial/uso terapêutico , Estatísticas não Paramétricas , Cremes Dentais/química
3.
Caries Res ; 40(2): 97-103, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16508265

RESUMO

The laser device DIAGNOdent developed for the detection of occlusal caries has limited value on approximal surfaces. The aim of this study was to develop and to test a new laser fluorescence (LF) device for the detection of approximal caries. Light with a wavelength of 655 nm was transported to the approximal surface using two different sapphire fibre tips. Seventy-five teeth were selected from a pool of extracted permanent human molars, frozen at -20 degrees C until use. Before being measured, they were defrosted, cleaned and calculus was removed with a scaler. The molars were set in blocks simulating the contact area of adults. Bitewing radiographs were obtained using Kodak Insight films. After two independent assessments with the new LF device, the teeth were histologically prepared, and assessed for caries extension. Using the laser, specificity values for D1 threshold (outer half of enamel), D2 threshold (inner half of enamel), D3 threshold (dentine) ranged between 0.81 and 0.93, sensitivity between 0.84 and 0.92 with no difference between the two tips. Bitewing radiography showed an inferior performance compared to LF (p<0.05). Intraex aminer reproducibility was high (kappa>.74). The new LF system might be a useful additional tool in detecting approximal caries. Because of its good reproducibility, it could be used to monitor caries regression or progression on approximal surfaces.


Assuntos
Testes de Atividade de Cárie Dentária , Cárie Dentária/diagnóstico , Fluorometria/instrumentação , Lasers , Adulto , Fluorescência , Humanos , Funções Verossimilhança , Dente Molar , Variações Dependentes do Observador , Radiografia Interproximal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Caries Res ; 38(6): 567-71, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15528913

RESUMO

The aim of this study was to test the effect of fluoride rinsing on the prevention of toothbrush abrasion of softened enamel in situ. For softening, the samples were immersed in 0.1 M citric acid (pH 3.5) for 3 min. Eight test subjects had to make 5 runs in which 4 slabs per run were attached to intraoral appliances. They were as follows: (1) no softening, no fluoride rinsing (control 1); (2) softening, no fluoride rinsing (control 2); (3) softening, rinsing in situ with a sodium/amine fluoride rinsing solution (250 ppm F) for 30 s; (4) rinsing in situ with the sodium/amine fluoride rinsing solution (250 ppm F) for 30 s, softening; (5) softening, rinsing in situ with an experimental amine fluoride-containing rinsing solution (250 ppm F) for 30 s. After exposure for 60 min to the oral milieu, the volunteers brushed the samples for 30 s with toothpaste and the loss of tooth substance was determined. For each test person, the secretion rate of resting and paraffin-stimulated saliva, buffering capacity and pH were measured. Toothbrush abrasion in situ was not significantly lower using the fluoride rinsing solutions before or after softening the enamel compared to no rinsing (p > 0.05). Multiple linear regression analyses revealed that 57% of the variation in toothbrush abrasion could be attributed to the severity of softening (p < 0.001) and the pH of stimulated saliva (p < 0.001). It was concluded that a single rinse for 30 s had no statistically significant effect on the prevention of toothbrush abrasion of softened enamel.


Assuntos
Fluoretos Tópicos/administração & dosagem , Antissépticos Bucais , Fluoreto de Sódio/administração & dosagem , Abrasão Dentária/prevenção & controle , Erosão Dentária/complicações , Escovação Dentária/efeitos adversos , Adulto , Análise de Variância , Dente Pré-Molar , Ácido Cítrico/farmacologia , Esmalte Dentário/efeitos dos fármacos , Solubilidade do Esmalte Dentário/efeitos dos fármacos , Dureza/efeitos dos fármacos , Humanos , Concentração de Íons de Hidrogênio , Análise de Regressão , Saliva/química , Saliva/metabolismo , Abrasão Dentária/etiologia
5.
Eur J Oral Sci ; 109(1): 14-9, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11330928

RESUMO

Children and adolescents must be examined often for occlusal caries. Diagnosis of fissure caries is difficult especially when the tooth surface appears seemingly intact. It has been shown that using traditional clinical methods, as little as 20% of teeth with fissure caries under intact surfaces were correctly recognised as such. Therefore, new methods for increasing the accuracy of diagnosis have been sought for years. Recently, a new device, based on fluorescence measurements, was introduced. The purpose of this study was to test the device under in vivo conditions in order to provide recommendations for its use in the dental office. Seven general dental practitioners examined a total of 332 occlusal surfaces in 240 patients. Caries extent was determined for each site after operative intervention (='gold standard'). Clinical inspection and analysis of bitewing radiographs exhibited statistically significant lower sensitivities (31-63%) than did the DIAGNOdent device (sensitivity > or = 92%). It is recommended that the laser device is used in the decision-making process in relation to the diagnosis of occlusal caries as a second opinion in cases of doubt after visual inspection.


Assuntos
Cárie Dentária/diagnóstico , Diagnóstico Bucal/instrumentação , Lasers , Adolescente , Adulto , Criança , Fluorescência , Humanos , Variações Dependentes do Observador , Radiografia Interproximal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatísticas não Paramétricas
6.
Eur J Oral Sci ; 108(2): 110-4, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10768723

RESUMO

The aim of this study was to compare the erosive potential of different beverages and foodstuffs in primary and permanent teeth. Sixty primary and 60 permanent human teeth were immersed for 3 min in the solution under study (5 teeth per treatment group). Surface microhardness was measured before and after exposure. Initial (baseline) surface microhardness was lower for primary teeth than for permanent teeth. In both primary and permanent teeth, Sprite showed the highest decrease in surface microhardness, whereas yogurt showed an increase in surface microhardness in the primary teeth. Overall decrease was 27.2 +/- 17.5 KHN (mean +/- SD) for primary and 25.9 +/- 15.6 KHN for permanent teeth. The comparison of the erosive susceptibility in this in vitro model showed that primary teeth were not more susceptible to erosion compared to permanent teeth.


Assuntos
Bebidas/efeitos adversos , Erosão Dentária/etiologia , Dente Decíduo/patologia , Bebidas/análise , Dente Pré-Molar/patologia , Soluções Tampão , Cálcio/análise , Bebidas Gaseificadas/efeitos adversos , Bebidas Gaseificadas/análise , Citrus , Esmalte Dentário/patologia , Suscetibilidade a Doenças , Fluoretos/análise , Frutas , Dureza , Humanos , Concentração de Íons de Hidrogênio , Imersão , Dente Molar/patologia , Fósforo/análise , Chá/química , Coroa do Dente/patologia , Iogurte/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...